CobraNet Indicators and Their Significance
Check for proper operation of a CobraNet® device by checking the following indicators:
- Check the power indicator to ensure that the device is receiving the proper power supply. Power indicators can vary by specific product.
- Check indicator lights on the connected switches to make sure a good link exists and that the data rate is at least 100 Megabits. For a description of switch indicators, refer to the manual provided by your switch manufacturer.
- Check the RJ-45 connection indicator lights for your CobraNet interface device as detailed below. Please note: if your device has two RJ-45 connections (the most common case), the lights for each connection will behave identically.
CM-1 Devices
Up to Rev E. Board
| Condition |
Left LED |
Right LED |
| Conductor |
Flashing Green |
Solid Orange |
| Performer |
Flashing Orange |
Solid Green |
| Fault |
Flashing Red |
Flashing Red |
CM-2, Silicon Series or CM-1 Rev F (and later) Devices
| Condition |
Left LED |
Right LED |
| Conductor |
Flashing Orange |
Flashing Green |
| Performer |
Solid Orange |
Flashing Green |
| Fault |
Flashing Orange |
Flashing Orange |